Model | | S-15-5 | S-15-12 | S-15-15 | S-15-24 | |
Output | DC output Voltage | 5V | 12V | 15V | 24V | |
Voltage tolerance | ±2.0% | ±2.0% | ±2.0% | ±1.0% | |
Rated Current | 3A | 1.3A | 1A | 0.7A | |
Related Power | 15w | 15w | 15w | 15w | |
Wave&Noise | 50mVp-p | 50mVp-p | 50mVp-p | 100mVp-p | |
Adjustable range for DC Voltage | ±10% | ±10% | ±10% | ±10% | |
Set up,rise,hold up time | 200ms 100ms 30ms | |
Input | Voltage Range | 85 ~132VAC 170-264VAC 47-63HZ 240-370VDC | |
Input Current | 0.5A/115VAC 0.25A/230VAC | |
Efficiency | 65% | 68% | 68% | 72% | |
AC inrush current | Cold start current 15A/115V 30A /230VAC | |
Leakage current | <0.5mA/240VAC | |
Protection | Overload | Related output power 105-150% start overload protection | |
Protection type: cutoff output, recovery after restart power | |
Over voltage | 5.75V-6.75V | 13.8V-16.2V | 17.2V-20.2V | 27.6V-32.4V | |
Hiccup mode,recovers automatically after fault condition | |
Environment | Working temp humidity | -10~+60°C 20%~90%RH | |
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |
Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |
I/P-FG:1.5KVAC 1min | |
O/P-FG:0.5KVAC 1min | |
Standard | Safety standard | Fit UL1012 | |
Refer | Design refer to GB4943,UL60950,EN60950 | |
EMC standard | Design refer to GB9254,EN55022 Class A | |
Size | size | L99*W97*H35mm | |
Package | 0.3kg, 60 pcs/18kg | |
| |
Model | | S-25-5 | S-25-12 | S-25-15 | S-25-24 | |
Output | DC output Voltage | 5V | 12V | 15V | 24V | |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Rated Current | 5A | 2.1A | 1.7A | 1.1A | |
Related Power | 25w | 25w | 25w | 25w | |
Wave&Noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
Adjustable range for DC Voltage | ±10% | ±10% | ±10% | ±10% | |
Set up,rise,hold up time | 200ms 100ms 30ms | |
Input | Voltage Range | 85 ~132VAC 170-264VAC 47-63HZ 240-370VDC | |
Input Current | 0.5A/115VAC 0.25A/230VAC | |
Efficiency | 68% | 68% | 68% | 72% | |
AC inrush current | Cold start current 15A/115V 30A /230VAC | |
Leakage current | <0.5mA/240VAC | |
Protection | Overload | Related output power 105-150% start overload protection | |
Protection type: cutoff output, recovery after restart power | |
Over voltage | 5.75V-6.75V | 13.8V-16.2V | 17.2V-20.2V | 27.6V-32.4V | |
Hiccup mode,recovers automatically after fault condition | |
Environment | Working temp humidity | -10~+60°C 20%~90%RH | |
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |
Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |
I/P-FG:1.5KVAC 1min | |
O/P-FG:0.5KVAC 1min | |
Standard | Safety standard | Fit UL1012 | |
Refer | Design refer to GB4943,UL60950,EN60950 | |
EMC standard | Design refer to GB9254,EN55022 Class A | |
Size | size | L99*W97*H35mm | |
Package | 0.3kg, 60 pcs/18kg | |
| |
MODEL | S-35-5 | S-35-12 | S-35-15 | S-35-24 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | |
RATED CURRENT | 7A | 3A | 2.4A | 1.5A | |
RATED POWER | 35W | 36W | 36W | 36W | |
RIPPLE&NOISE | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
VOLTAGE ADJ.RANGE | 4.75-5.5V | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V | |
VOLTAGE TOLERANCE | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5 | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±0.5% | ±0.5% | ±0.5% | |
SETUP,RISE TIME | 300ms,50ms/230VAC 800ms,50ms/115VAC at full load | |
HOLD UP TIME(TYP.) | 90ms/230VAC 12ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 85-264VAC 120-370VDC | |
FREQUENCY RANGE | 47-63HZ | |
EFFICIENCY(Typ.) | 70% | 76% | 78% | 78% | |
AC CURRENT(Typ.) | 0.8A/115VAC 0.45A/230VAC | |
INRUSH CURRENT | COLD START 15A/115VAC 30A/230VAC | |
LEAKAGE CURRENT | 2mA/240VAC | |
PROTECTION | OVERLOAD | 105-150% RATED OUTPUT POWER | |
| Protection type:Hiccup mode,recovers automatically after fault condition | |
OVER VOLTAGE | 5.75V-6.75V | 13.8V-16.2V | 17.2V-20.25V | 27.6V-32.4V | |
| Protection type:Hiccup mode,recovers automatically after fault condition | |
ENVIRONMENT | WORKING TEMP | -10~+60°C | |
WORKING HUMIDITY | 20-90%RH non-condesing | |
STORAGE TEMP,HUMIDITY | -20~+85°C,10-95%RH | |
TEMP.COEFFICIENT | ±0.03%°C(0-50°C) | |
VIBRATION | 10-500HZ | |
SAFETY&EMC | SAFETY STANDARD | CE RoHS | |
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1minute | |
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25°C/70%RH | |
EMI CONDUCTION&RADIATION | Design refer to GB4943,UL60950,EN60950 | |
EMC STANDARD | Design refer to GB9254,EN55022 Class A | |
DIMENSION | L129*W98*H38mm | |
PACKING | 0.4kg,45pcs/18kg | |
Model | | S-50-5 | S-50-12 | S-50-15 | S-50-48 | |
Output | DC output Voltage | 5V | 12V | 15V | 48V | |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Rated Current | 10A | 4.2A | 3.4A | 1A | |
Related Power | 50w | 50w | 50w | 50w | |
Wave&Noise | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
Adjustable range for DC Voltage | ±10% | ±10% | ±10% | ±10% | |
Set up,rise,hold up time | 200ms 100ms 30ms | |
Input | Voltage Range | 85 ~132VAC 170-264VAC 47-63HZ 240-370VDC | |
Input Current | 1.2A/115VAC 0.6A/230VAC | |
Efficiency | 71% | 78% | 78% | 82% | |
AC inrush current | Cold start current 15A/115V 30A /230VAC | |
Leakage current | <0.5mA/240VAC | |
Protection | Overload | Related output power 105-150% start overload protection | |
| Protection type: cutoff output, recovery after restart power | |
Over voltage | 5.75V-6.75V | 13.8V-16.2V | 17.2V-20.2V | 27.6V-32.4V | |
| Hiccup mode,recovers automatically after fault condition | |
Environment | Working temp humidity | -10~+60°C 20%~90%RH | |
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |
Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |
| I/P-FG:1.5KVAC 1min | |
O/P-FG:0.5KVAC 1min | |
Standard | Safety standard | Fit UL1012 | |
Refer | Design refer to GB4943,UL60950,EN60950 | |
EMC standard | Design refer to GB9254,EN55022 Class A | |
Size | size | L159*W98*H38mm | |
Package | 0.5kg, 40pcs/20kg | |
Model | | S-60-5 | S-60-12 | S-60-15 | S-60-48 | |
Output | DC output Voltage | 5V | 12V | 15V | 48V | |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Rated Current | 12A | 5A | 4A | 1.25A | |
Related Power | 60w | 60w | 60w | 60w | |
Wave&Noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
Adjustable range for DC Voltage | ±10% | ±10% | ±10% | ±10% | |
Set up,rise,hold up time | 200ms 100ms 20ms | |
Input | Voltage Range | 85~132VAC 170-264VAC selected by switch 47-63HZ 240-370VDC | |
Input Current | 2A/115VAC 1A/230VAC | |
Efficiency | 78% | 78% | 78% | 82% | |
AC inrush current | Cold start current 15A/115V 30A /230VAC | |
Leakage current | <0.5mA/240VAC | |
Protection | Overload | Related output power 105-150% start overload protection | |
| Protection type: cutoff output, recovery after restart power | |
Over voltage | 5.75V-6.75V | 13.8V-16.2V | 17.2V-20.2V | 27.6V-32.4V | |
| Hiccup mode,recovers automatically after fault condition | |
Environment | Working temp humidity | -10~+60°C 20%~90%RH | |
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |
Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |
| I/P-FG:1.5KVAC 1min | |
O/P-FG:0.5KVAC 1min | |
Standard | Safety standard | Fit UL1012 | |
Refer | Design refer to GB4943,UL60950,EN60950 | |
EMC standard | Design refer to GB9254,EN55022 Class A | |
Size | size | L159*W98*H38mm | |
Package | 0.5kg, 30pcs/15kg | |
Model | | S-75-5 | S-75-12 | S-75-15 | S-75-24 | |
Output | DC output Voltage | 5V | 12V | 15V | 24V | |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Rated Current | 15A | 6.3A | 5A | 3.2A | |
Related Power | 75w | 75w | 75w | 75w | |
Wave&Noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
Adjustable range for DC Voltage | ±10% | ±10% | ±10% | ±10% | |
Set up,rise,hold up time | 200ms 100ms 20ms | |
Input | Voltage Range | 85~132VAC 170-264VAC selected by switch 47-63HZ 240-370VDC | |
Input Current | 1.6A/115VAC 0.8A/230VAC | |
Efficiency | 68% | 68% | 72% | 82% | |
AC inrush current | Cold start current 15A/115V 30A /230VAC | |
Leakage current | <0.5mA/240VAC | |
Protection | Overload | Related output power 105-150% start overload protection | |
| Protection type: cutoff output, recovery after restart power | |
Over voltage | 5.75V-6.75V | 13.8V-16.2V | 17.2V-20.2V | 27.6V-32.4V | |
| Hiccup mode,recovers automatically after fault condition | |
Environment | Working temp humidity | -10~+60°C 20%~90%RH | |
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |
Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |
| I/P-FG:1.5KVAC 1min | |
O/P-FG:0.5KVAC 1min | |
Standard | Safety standard | Fit UL1012 |
Refer | Design refer to GB4943,UL60950,EN60950 |
EMC standard | Design refer to GB9254,EN55022 Class A |
Size | size | L159*W98*H38mm |
Package | 0.5kg, 30pcs/15kg |
Model | | S-100-7.5 | S-100-12 | S-100-15 | S-100-24 | S-100-48 | |
Output | DC output Voltage | 7.5V | 12V | 15V | 24V | 48V | |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Rated Current | 13.3A | 8.5A | 6.7A | 4.5A | 2A | |
Related Power | 100w | 100w | 100w | 100w | 100w | |
Wave&Noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
Adjustable range for DC Voltage | ±10% | ±10% | ±10% | ±10% | ±10% | |
Set up,rise,hold up time | 200ms 100ms 20ms | |
Input | Voltage Range | 85~132VAC 170-264VAC selected by switch 47-63HZ 240-370VDC | |
Input Current | 1.6A/115VAC 0.8A/230VAC | |
Efficiency | 81% | 81% | 84% | 84%% | 84% | |
AC inrush current | Cold start current 15A/115V 30A /230VAC | |
Leakage current | <0.5mA/240VAC | |
Protection | Overload | Related output power 105-150% start overload protection | |
Protection type: cutoff output, recovery after restart power | |
Over voltage | 5.75V-6.75V | 13.8V-16.2V | 17.2V-20.2V | 27.6V-32.4V | 55V-64.8V | |
Hiccup mode,recovers automatically after fault condition | |
Environment | Working temp humidity | -10~+60°C 20%~90%RH | |
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |
Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |
I/P-FG:1.5KVAC 1min | |
O/P-FG:0.5KVAC 1min | |
Standard | Safety standard | Fit UL1012 | |
Refer | Design refer to GB4943,UL60950,EN60950 | |
EMC standard | Design refer to GB9254,EN55022 Class A | |
Size | size | L199*W98*H38mm | |
Package | 0.65kg, 30pcs/19kg | |
Model | | S-120-5 | S-120-12 | S-120-15 | S-120-24 | S-120-48 | |
Output | DC output Voltage | 5V | 12V | 15V | 24V | 48V | |
Voltage tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Rated Current | 24A | 10A | 8A | 5A | 2.5A | |
Related Power | 120w | 120w | 120w | 120w | 120w | |
Wave&Noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
Adjustable range for DC Voltage | ±10% | ±10% | ±10% | ±10% | ±10% | |
Set up,rise,hold up time | 200ms 100ms 20ms | |
Input | Voltage Range | 85 ~132VAC 170-264VAC 47-63HZ 240-370VDC | |
Input Current | 2.4A/115VAC 1.2A/230VAC | |
Efficiency | 81% | 81% | 84% | 84%% | 84% | |
AC inrush current | Cold start current 30A/115V 60A/230VAC | |
Leakage current | <0.5mA/240VAC | |
Protection | Overload | Related output power 105-150% start overload protection | |
Protection type: cutoff output, recovery after restart power | |
Over voltage | 5.75V-6.75V | 13.8V-16.2V | 17.2V-20.2V | 27.6V-32.4V | 55V-64.8V | |
Hiccup mode,recovers automatically after fault condition | |
Environment | Working temp humidity | -10~+60°C 20%~90%RH | |
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |
Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |
I/P-FG:1.5KVAC 1min | |
O/P-FG:0.5KVAC 1min | |
Standard | Safety standard | Fit UL1012 | |
Refer | Design refer to GB4943,UL60950,EN60950 | |
EMC standard | Design refer to GB9254,EN55022 Class A | |
Size | size | L199*W98*H38mm | |
Package | 0.65kg, 30pcs/20kg | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |